LIP series for very high accuracy

ModelBasline errorSubstrate and mountingInterpolation errorMeasuring length
Accuracy gradeIntervall
LIP 382± 0.5 μm≤ ± 0.075 μm/ 5 mmZerodur glass ceramic embedded in bolted-on Invar carrier

 

± 0.01 nm70 mm to 270 mm
LIP 211
LIP 281

LIP 291
± 1 μm
± 3 μm
≤ ± 0.125 μm/ 5 mmScale of Zerodur glass ceramic with fixing clamps

 

± 1 nm20 mm to 3040 mm
LIP 6071 LIP 6081±1 μm (bis Messlänge 1020 mm); ±3 μm≤ ± 0.175 μm/ 5 mmScale of Zerodur glass ceramic, by adhesive or fixing clamps ± 3 nm20 mm to 3040 mm